OPERATION
CAUTION: The electrode measurement pins are extremely sharp. Use
care when handling this instrument. Cover the pins with the
protective cap when the instrument is not in use.
MEASURING PROCEDURE:
The electrode pins must be inserted before the meter can be used.
To insert or replace the pins refer to the instructions below:
Remove the protective cap at the top of the unit
To remove the pins, loosen the locknut at the base of the
electrode pins
Install the new pins and tighten the locknuts
Replace the protective cap
OPERATION:
Remove the protective cap away from the test pins
Press the POWER button to turn the unit on
Press the “Material” button to select the desired testing material
Material 1: 0 to 100% relative moisture value for concrete and other
non-wood material. A ‘1’ will display on the bottom right.
Material 2: 6% to 40% moisture range for wood. A ‘2’ will display on
the bottom right.
It is recommended that the test pins are to be inserted to a minimum
depth of 1/8" (.125") into the material under test. If a depth of 1/8"
(.125") can not be obtained, then insert the test pins to their
maximum achievable depth.
Display will show the moisture contents in “% moisture content”
directly.
Consideration: If the sample test has high moisture content, it may
take a few minutes to obtain a stable reading.
Replace the protective cap when finished.