General-tools-and-instruments NGD8800 Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
COMBUSTIBLE GAS DETECTOR
4
Warm-Up Time: Approximately 90 seconds
Operating Temperature & Humidity:
32° to 104°F (0° to 40°C), < 80% RH
Storage Temperature & Humidity:
14° to 140°F (-10° to 60°C), < 70% RH
Altitude: <6500 ft. (2000m)
4. OPERATION GUIDE
(1) This combustible gas detector unit is NOT designed
for anti-explosive measures. Do not use this unit in an
area where combustible gases can be found.
(2) The following environmental conditions may cause
error in the readings:
Large temperature variations
High wind velocity
Organic solvents, adhesive vapors, fuel gas and
vesicants. Try to avoid environments filled with
these substances.
Places filled with too much combustible gas
Note: Although this unit will respond to high levels of
carbon monoxide, it should NOT be used as a detector
for this gas in normal room or working atmospheres. It
is used to pinpoint a leak as described in the operating
instruction.
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 15 16

Comentarios a estos manuales

Sin comentarios