SAFETY RULES:
The DMM51FSG complies with IEC 1010-1 CAT I 1000V, CAT II 600V and CAT III
300V overvoltage standards. Use the meter only as specified in this manual,
otherwise the protection provided by the meter may be impaired.
CAT I - For signal level, telecommunication, electronic with small transient over
voltage.
CAT II - For local level, appliances, main wall outlets, portable equipment.
The meter is designed to withstand the stated maximum voltages. For Safety
reasons,do not exceed the maximum stated voltage ranges.
Do not operate the meter before the casing has been closed and screwed safely as
the terminals can carry voltage.
Make sure the meter is set to the correct range before taking each measurement.
Before using the meter, please inspect the case and test leads for damaged
insulation or exposed metal.
Connect the red and black test lead to the correct measuring input jack properly.
Do not input values over the maximum range of each measurement scale to avoid
damages of the meter.
Do not turn the rotary function switch during Voltage and Current measurement,
otherwise the meter could be damaged.
Make sure to use new fuses with proper rating. Do not use incorrect fuses.
To avoid electric shock or damages, do not apply more than 1000V between the
COM terminals and earth ground .
Use caution when working with Voltages above 60V (DC) or 30Vrms (AC). These
Voltages pose shock hazard.
Replace the battery as soon as the battery indicator icon appears. With a
low battery, the meter might produce false readings that can lead to electric shock
and personal injury.
Turn off the meter once finished measuring. Take out the battery, when the meter
will not be used for long period.
Do not operate the meter under adverse environmental conditions such as
excessive humidity.
To avoid damage and dangerous operation, do not alter or change the circuit.
To clean, periodically wipe the case with a damp cloth and mild detergent. Do not
use abrasives or solvents.
International Electrical Symbols:
Low Battery Earth Ground
Safety Rules Double Insulated
AC Diode
Dangerous Voltages Buzzer
DC Fuse
DMM51FSG Manual FINAL-091908:Layout 1 9/19/08 4:03 PM Page 2