6-2 Call data1)Turn on the meter.Press the " Hold Button " ( 3-3, Fig. 1 ) momentarily, LCD shows " HOLD ". Following, press the
6-3 Delete data ( Empty the memory )1)Turn off the meter first.2)Press the " REC Button " ( 3-4, Fig. 1 ) continuously andnot release, at th
7. BATTERY REPLACEMENT * Replace the batteries when the left corner of the LCDdisplays the low battery icon " ", using 4 fresh 1.
TABLE OF CONTENTS1. FEATURES... 12. SPECIFICATIONS...
1. FEATURES* Cup vane anemometer, available for wind speedmeasurement, high reliability.* Measurement range : 0.9 to 35.0 m/s* Wind speed unit : m/s,
Temp. Sensor ThermisterData Logger Max. can save 100 point data with recall.Manual, push the data logger button once will save data one time.Sensor Cu
b. TemperatureMeasuring Range 0 to 50 /32 to 122 ℃℃℉ ℉Resolution 0.1 /0. 1 ℃℉Accuracy ± 0.8 /1.5 ℃℉3. FRONT PANEL DESCRIPTIONFig. 13-1 Cup Vane3-
4. INSTALL THE VANE CUPRotate the topscrew incounterclockwisedirection untilthe screw issecured.4
5. MEASURING PROCEDURE 5-1 Wind speed and Temp. measurement1)Turn on the meter by pressing the " Power Button "( 3-2, Fig. 1 ) momentarily.
5-4 Data Hold* During the measurement, press the " Hold Button "( 3-3, Fig. 1 ) momentarily to hold the measuredvalue. The LCD will show a
6. DATA LOGGERThe meter can save max. 100 point data into the the memory circuit6-1 Save data1)Turn on the meter.2)Press the " REC Button "