General-tools-and-instruments WDCFM8912 Manual de usuario

Busca en linea o descarga Manual de usuario para Herramientas General-tools-and-instruments WDCFM8912. General Tools and Instruments WDCFM8912 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
WDCFM8912
USER’S MANUAL
DIGITAL AIR FLOW METER WITH
CFM, BTU, TEMP, HUMIDITY, DP, FPM,
MPH, KPH, MPS, KNOTS & WET BULB
WDCFM8912 Manual final2F-062708:Layout 1 6/27/08 10:55 AM Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - WDCFM8912

WDCFM8912USER’S MANUALDIGITAL AIR FLOW METER WITHCFM, BTU, TEMP, HUMIDITY, DP, FPM,MPH, KPH, MPS, KNOTS & WET BULBWDCFM8912 Manual final2F-062708:

Pagina 2 - INTRODUCTION

RS232 SOFTWARESOFTWAREWe have compatible software and cable which is design for themeter, please contact your supplier for details.INTERFACE OF RS232A

Pagina 3 - O more than two sec. to

6. E 6a) the value is not calculated completely.7. E 11a) Humidity Calibration error.SPECIFICATIONTEMPERATURE: -4º to 140ºF (-20º to 60ºC)Accuracy: ±1

Pagina 4

2. If the saved S value is different from your paper, pressMHOLDkeyto move to the digit which you want to edit and then useLMx/Mnkey to change the val

Pagina 5 - MAX, MIN & AVG

User should also input four digits before decimal. All the Z is anegative value but LCD will not appear the negative icon. Example:1. If the Z value i

Pagina 6 - AIR VOLUME: MEASUREMENT

NOTES_________________________________________________________________________________________________________________________________________________

Pagina 7 - CAPACITY: OUTLET SIZE

______________________________________________________________________________________________________________________________________________________

Pagina 8 - CAPACITY: MEASUREMENT

General TOOLS & INSTRUMENTS™80 White Street, New York,NY10013-3567PHONE (212) 431-6100FAX (212) 431-6499TOLL FREE (800) 697-8665e-mail: sales@gene

Pagina 9 - AVAILABLE SIZE RANGE

INTRODUCTIONThank you for purchasing this digital Anemo-Psychrometer.This unique meter is designed with 7 H.V.A.C &R that must haveparameters in 1

Pagina 10 - TROUBLESHOOTING

REMINDERIMPORTANT:1. Rotate the cover before measurement toensure the measured data is correct.2. The fan and meter are sold as a kit andare calibrate

Pagina 11 - FAN REPLACEMENT

3. ENTER:- To confirm the setting & calibration.4. Mx/Mn/UpLMx/Mn:- Pressing to view MAX/MIN/AVG value.- Press to select the value of each digit i

Pagina 12

BASIC MEASUREMENTBasic measured parameters of this model:BASIC MEASUREMENTS• Air temp.• Humidity• Dew Point• Wet Bulb• Air VelocityEXTENDED MEASUREMEN

Pagina 13 - RETURN AUTHORIZATION

AIR VOLUME: OUTLET SIZEWhile in normalMODE, long pressingMODEkey to enter air volumemode.To measure the volume, the outlet size needs to be input firs

Pagina 14

displayed on top left corner andmeter also beeps when time isup. (Fig. F)If no need to wait for 20seconds, just pressREC/STARTkey to start measuring t

Pagina 15

• Diameter:While in default outlet setting mode (length), pressingENTERkeyfor over two seconds to choose diameter setting. PressMHOLDkeyto select the

Pagina 16 - WDCFM8912 User’s Manual

During this 60 second time, the vane should move along the wholeoutlet to cover each area so the measured data could be moreaccurate. The count down n