NON-CONTACT
VOLTAGE DETECTOR
WITH ADJUSTABLE
SENSITIVITY AND
IR THERMOMETER
USERS MANUAL
VR40
Please read this manual carefully and thoroughly
before using this product.
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - USER’S MANUAL

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLESENSITIVITY AND IR THERMOMETERUSER’S MANUALVR40Please read this manual carefully and thoroughly before usi

Pagina 2 - TABLE OF CONTENTS

WHAT’S IN THE BLISTER PACKThe VR40 comes fully assembled in a blister pack alongwith (2) “AAA” batteries and this user’s manual.PRODUCT OVERVIEWFig. 1

Pagina 3 - INTRODUCTION

1 Non-contact voltage (NCV) detection blade tip2 NCV detection LED (glows red)3 LCD 4 Two-function IRT button: 1) Pressed by itself (brieflyor held),

Pagina 4

9 Infrared sensor10 Battery compartment11 Pocket clipFig. 2. All possible display indications.Data hold onIR temperature readout onNon-contact voltage

Pagina 5

SETUP INSTRUCTIONSINSTALL BATTERIESThe VR40’s battery compartment (Fig. 1, Callout 10) isaccessible from the back of the unit.To open the compartment,

Pagina 6 - KEY FEATURES

batteries are charged, the beeper will sound repeatedlyand the red LED under the translucent cap (Fig. 1,Callout 2) will flash when the tip is in one

Pagina 7 - • WARNING •

The figure below also shows which slots of two othercommon 110VAC receptacles are hot. In both cases,the “hot” slot is on the right and smaller.2. If

Pagina 8

To detect the presence of AC voltage on anindividual line or cable, position the blade tip within1/4 inch of the line or cable and press and hold theN

Pagina 9

measured temperature will be displayed on the LCD,along with the icon on the top line.When you make temperature measurements, be sure to get close en

Pagina 10 - PRODUCT OVERVIEW

To eliminate measurement error, the VR40 must bemoved close enough to the target so it is the only objectin the target area. The figure below illustra

Pagina 11

To change the temperature unit, press the NCV andIRT buttons at the same time. Each simultaneous presswill toggle the unit between °C and °F. The sele

Pagina 12

TABLE OF CONTENTSIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . 3 –6Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 13 - OPERATING INSTRUCTIONS

Measurement Accuracy: ±3°F (2°C) or ±1% of reading(whichever is greater) above 32°F; ±4.5°F (2.5°C)below 32°FIRT Emissivity: Fixed at 0.95IR Sensor Sp

Pagina 14

• If the temperature of the IRT’s target is lower than -4°F (-20°C)—the lower limit of the unit’smeasurement range—“LO” will appear on thereadout.• If

Pagina 15

WARRANTY INFORMATIONGeneral Tools & Instruments’ (General’s) VR40 Non-contact Voltage Detector with Adjustable Sensitivityand IR Thermometer is wa

Pagina 16

RETURN FOR REPAIR POLICYEvery effort has been made to provide you with areliable product of superior quality. However, in theevent your instrument req

Pagina 17

GENERAL TOOLS & INSTRUMENTS80 White StreetNew York, NY 10013-3567PHONE (212) 431-6100FAX (212) 431-6499TOLL FREE (800) 697-8665e-mail: sales@gener

Pagina 18

INTRODUCTIONThank you for purchasing General Tools & Instruments’(General’s) VR40 Non-contact Voltage Detector withAdjustable Sensitivity and IR T

Pagina 19 - SPECIFICATIONS

Unlike other NCV detectors with only one sensitivitylevel—and therefore the ability to detect only one rangeof voltages (typically 50 to 600VAC)—Gener

Pagina 20 - MAINTENANCE TIPS

Merely detecting the presence of 120VAC near a bundleof wires does not tell you which wire of the bundle isthe “hot” wire; any of the wires could be a

Pagina 21

• A unique, patent-pending ergonomic design thatplaces the IR and NCV sensors and the flashlight onthe same end of the instrument.KEY FEATURES• Dual i

Pagina 22 - WARRANTY INFORMATION

SAFETY INSTRUCTIONS• WARNING •• You must confirm that the batteries powering theVR40 are not weak or dead before you use the unit totest for the prese

Pagina 23 - RETURN FOR REPAIR POLICY

• Physically separate the multiple lines of 2-phase and3-phase circuits before testing them.• Do not use the VR40 if it appears to be damaged ormalfun

Pagina 24 - TOLL FREE (800) 697-8665

The VR40 is a Class 2 laser product that emits lessthan 1mW of radiation at a wavelength between 630and 650nm. Avoid looking directly at the laser poi